Clinics

Through our colleagues at medekit
Frontier Medical is able to supply our own fully operational clinics, using transportable structures, tailor-designed to house a
fully-equipped remote site medical unit. | |
These transportable clinics are widely used within the oil and gas industry and are effective
in any climate and location. To withstand colder climates the buildings are equipped with high-quality insulation and heaters, in warmer climates air-conditioning systems are used. The units are low maintenance, durable, can cope with extreme weather conditions and have an expected life span in excess of 20 years.
The buildings are structured on ISO standard size containers and can be shipped and relocated any
where in the world. The units can be transported by lorry and 'skid mounted'(dragged into place) without
the need for any specialised lifting equipment.

The buildings can be custom designed and equipped with a tailored specification depending
on each set of circumstances. Fully constructed units with furnishings can be
provided as well as toilets, showers, baths and sinks already in place.
Each unit is designed to meet the individual requirements of each client. Lead-time
and delivery options are calculated on a case-to-case basis with average manufacturing
time currently 45 days.
Clinic Structure
Frame/Shell
| | • | A refurbished ISO standard shipping container is the basic steel framework for the containerised building shell. All external openings for windows, doors, etc are cut and framed with box steel tubing. All external additions, i.e. windows, doors, electrical and plumbing connectors are recessed within the required ISO measurements; |
| | • | Welds meet the welding codes for structural welding of this type; |
| | • | All steel grit blasted to SA2.5 and finished as follows:
|
| | | - | underside - painted with coal tar epoxy
|
| | | - | walls and roof - primer: 2-pack epoxy epoprime basecoat |
| | | - | mid coat and top coat: 2-pack polyurethane
|
Floor System
| | • | 12mm plywood decking is installed over the properly prepared container floor;
|
| | • | Sheet vinyl floor covering with welded seams is installed as the floor finish;
|
| | • | Ablution buildings include fiberglass floor finish.
|
Walls
| | • | 64mm thick composite panels insulated with polystyrene. These are installed around the perimeter exterior walls as well as utilised for the interior partitions, located as noted on plans;
|
| | • | All doors, windows, A/C openings and wall intersections are reinforces with internal SPF wood stud framing;
|
| | • | Composite panel walls are secured and trimmed to floor and roof system with PVC profiled flashings;
|
| | • | Door and window casings trimmed with PVC profiled flashings.
|
Ceiling
| | • | Ceiling is 64mm insulated composite panel secured to wall panel assembly by PVC profile flashings;
|
| | • | Ceiling panels are reinforced with internal wood stud framing on 1-meter centres.
|
Exterior Doors
| | • | 36" x 80" steel doors with insulated core, complete with frame, weather stripping, bunjee cords, cylindrical lockset and hinges.
|
Interior Doors
| | • | Interior doors are 30" x 78" standard size with 24" x 78" for baths. Doors are pre-finished hardboard exterior with honeycomb core, complete with privacy cylindrical lockset.
|
Windows
| | • | Aluminum framed, vertical sliding window, 30" x 27", standard all rooms except 14" x 27" obs in bathrooms;
|
| | • | All windows comply with safety standards and are polypropylene weather sealed;
|
| | • | All windows are provided with removable insect screens.
|
Electrical
| | • | All wiring in accordance with modular camp building practices, installed in surface mounted trunking;
|
| | • | Voltage, phase and Hz as per customers requirements;
|
| | • | Quick disconnect exterior connections on all panel boards;
|
| | • | Copper wires to all devices and fixtures with grounding system;
|
| | • | Interior light fixtures incandescent or florescent as required;
|
| | • | Weatherproof incandescent light at each exterior door.
|
Plumbing
| | • | All piping in accordance with modular camp building practices, surface mounted;
|
| | • | Hot and cold water supply piping CPVS spec DIN 8079;
|
| | • | Drain piping PVC spec BS 5255/5214;
|
| | • | Good quality fittings and fixtures located as shown on drawings;
|
| | • | Quick couple disconnects on water and sewer outlets;
|
| | • | Water heaters American manufactured, size as required.
|
| |